Product characteristics |
Laser protection class |
2 |
Housing |
rectangular |
Electrical data |
Operating voltage [V] |
18...30 DC |
Current consumption [mA] |
< 150 |
Protection class |
III |
Reverse polarity protection |
yes |
Typ. lifetime [h] |
50000 |
Inputs / outputs |
Number of inputs and outputs |
Number of digital outputs: 2; Number of analog outputs: 1 |
Outputs |
Total number of outputs |
2 |
Electrical design |
PNP |
Number of digital outputs |
2 |
Output function |
normally open / closed; (programmable) |
Max. current load per output [mA] |
200 |
Number of analog outputs |
1 |
Analog current output [mA] |
4...20; (scalable IEC 61131-2) |
Max. load [Ω] |
250 |
Analog voltage output [V] |
0...10; (scalable IEC 61131-2) |
Min. load resistance [Ω] |
5000 |
Short-circuit protection |
yes |
Type of short-circuit protection |
yes (non-latching) |
Overload protection |
yes |
Monitoring range |
Max. light spot width [mm] |
150 |
Max. light spot height [mm] |
150 |
Light spot dimensions refer to |
75 m |
Background suppression [m] |
75...150 |
Measuring/setting range |
Measuring range [m] |
1...75; (Reflector E21159) |
Sampling rate [Hz] |
1...33 |
Interfaces |
Communication interface |
IO-Link |
Transmission type |
COM2 (38,4 kBaud) |
IO-Link revision |
1.1 |
SDCI standard |
IEC 61131-9 |
Profiles |
Smart Sensor: Sensor Identification; Binary Data Channel; Process Value; Sensor Diagnosis |
SIO mode |
yes |
Required master port class |
A |
Process data analog |
1 |
Process data binary |
2 |
Min. process cycle time [ms] |
6 |
Supported DeviceIDs |
Type of operation |
DeviceID |
default |
810 |
|
Operating conditions |
Ambient temperature [°C] |
-10...60 |
Protection |
IP 67 |
Tests / approvals |
EMC |
|
Laser protection class |
2 |
Notes on laser protection |
Caution: |
Laser light |
Power: |
<= 4,0 mW |
Wave length: |
650 nm |
pulse: |
1,3 ns |
Do not stare into beam. |
|
Avoid exposure to the laser light. |
|
laser class: |
2 |
|
EN / IEC60825-1:2007 |
|
EN / IEC60825-1:2014 |
|
Complies with 21 CFR 1040 except for deviations pursuant to Laser Notice No. 50, dated June 2007. |
|
MTTF [years] |
106 |
Mechanical data |
Weight [g] |
312 |
Housing |
rectangular |
Dimensions [mm] |
59 x 42 x 52 |
Material |
housing: diecast zinc; front lens: glass; LED window: PC |
Lens alignment |
Side sensing |
Displays / operating elements |
Display |
Switching status |
2 x LED, yellow |
Power |
LED, green |
Distance, programming |
alphanumeric display, 4-digit |
|
Remarks |
Remarks |
cULus - Class 2 source required |
|
Pack quantity |
1 pcs. |
Electrical connection |
Connection |
Connector: 1 x M12; coding: A |
Other data |
Parameter |
Setting range |
Factory setting |
Uni |
m, feet |
m |
OU1 |
Hno, Hnc, Fno, Fnc |
Hno |
SP1 |
1.00...75.00 |
10.00 |
nSP1 |
1.00...75.00 |
8.00 |
FSP1 |
1.00...75.00 |
12.00 |
OU2 |
Hno, Hnc, Fno, Fnc, I, U |
I |
SP2 |
1.00...75.00 |
20.00 |
nSP2 |
1.00...75.00 |
18.00 |
FSP2 |
1.00...75.00 |
22.00 |
ASP |
0...75.00 |
0 |
AEP |
0...75.00 |
75.00 |
rATE [Hz] |
1...33 |
15 |
dS1 |
0...0.1...5 |
0 |
dr1 |
0...0.1...5 |
0 |
dS2 |
0...0.1...5 |
0 |
dr2 |
0...0.1...5 |
0 |
dFo |
0...0.1...5 |
0.2 |
dIS |
d1...3; rd1...3; OFF |
d3 |
|
Repeatability / Accuracy |
|
Repeatability of the measured values |
Accuracy |
1...25 m |
± 15 mm |
± 35 mm |
30 m |
± 15 mm |
± 35 mm |
40 m |
± 15 mm |
± 35 mm |
50 m |
± 19 mm |
± 39 mm |
60 m |
± 27 mm |
± 47 mm |
70 m |
± 43 mm |
± 63 mm |
|
Sampling rate |
|
Reflector |
33 Hz |
|
Repeatability / Accuracy |
|
Repeatability of the measured values |
Accuracy |
1...75 m |
± 15 mm |
± 35 mm |
|
Sampling rate |
|
Reflector |
1 Hz |
The values apply at |
|
Extraneous light on the object |
< 100 klx |
constant ambient conditions |
23 °C / 960 hPa |
minimum power-on time in minutes |
10 |
|